In
nuclear magnetic resonance (NMR) spectroscopy, the chemical shift is the
resonant frequency of an
atomic nucleus
The atomic nucleus is the small, dense region consisting of protons and neutrons at the center of an atom, discovered in 1911 by Ernest Rutherford at the Department_of_Physics_and_Astronomy,_University_of_Manchester , University of Manchester ...
relative to a standard in a
magnetic field
A magnetic field (sometimes called B-field) is a physical field that describes the magnetic influence on moving electric charges, electric currents, and magnetic materials. A moving charge in a magnetic field experiences a force perpendicular ...
. Often the position and number of chemical shifts are diagnostic of the structure of a
molecule
A molecule is a group of two or more atoms that are held together by Force, attractive forces known as chemical bonds; depending on context, the term may or may not include ions that satisfy this criterion. In quantum physics, organic chemi ...
. Chemical shifts are also used to describe signals in other forms of spectroscopy such as
photoemission spectroscopy.
Some atomic nuclei possess a
magnetic moment
In electromagnetism, the magnetic moment or magnetic dipole moment is the combination of strength and orientation of a magnet or other object or system that exerts a magnetic field. The magnetic dipole moment of an object determines the magnitude ...
(
nuclear spin
Nuclear may refer to:
Physics
Relating to the nucleus of the atom:
* Nuclear engineering
* Nuclear physics
* Nuclear power
* Nuclear reactor
* Nuclear weapon
* Nuclear medicine
*Radiation therapy
*Nuclear warfare
Mathematics
* Nuclear space
* ...
), which gives rise to different
energy level
A quantum mechanics, quantum mechanical system or particle that is bound state, bound—that is, confined spatially—can only take on certain discrete values of energy, called energy levels. This contrasts with classical mechanics, classical pa ...
s and resonance frequencies in a magnetic field. The total magnetic field experienced by a nucleus includes local magnetic fields induced by currents of electrons in the
molecular orbitals (electrons have a magnetic moment themselves). The electron distribution of the same type of nucleus (e.g. ) usually varies according to the
local geometry (binding partners,
bond length
In molecular geometry, bond length or bond distance is defined as the average distance between Atomic nucleus, nuclei of two chemical bond, bonded atoms in a molecule. It is a Transferability (chemistry), transferable property of a bond between at ...
s, angles between bonds, and so on), and with it the local magnetic field at each nucleus. This is reflected in the spin energy levels (and resonance frequencies). The variations of nuclear magnetic resonance frequencies of the same kind of nucleus, due to variations in the electron distribution, is called the chemical shift. The size of the chemical shift is given with respect to a reference frequency or reference sample (see also
chemical shift referencing), usually a molecule with a barely distorted electron distribution.
Operating frequency
The operating (or Larmor) frequency
of a magnet (usually quoted as absolute value in MHz) is calculated from the
Larmor equation
:
where is the induction of the magnet (SI units of
tesla), and
is the
magnetogyric ratio of the nucleus an empirically measured fundamental constant determined by the details of the structure of each nucleus. For example, the proton operating frequency for a 1-tesla magnet is calculated as
:
MRI scanners are often referred to by their field strengths (e.g. "a 7 T scanner"), whereas
NMR spectrometers are commonly referred to by the corresponding proton Larmor frequency (e.g. "a 300 MHz spectrometer", which has a of 7 T). While chemical shift is referenced in order that the units are equivalent across different field strengths, the actual frequency separation in
hertz
The hertz (symbol: Hz) is the unit of frequency in the International System of Units (SI), often described as being equivalent to one event (or Cycle per second, cycle) per second. The hertz is an SI derived unit whose formal expression in ter ...
scales with field strength (). As a result, the difference of chemical shift between two signals (ppm) represents a larger number of hertz on machines that have larger , and therefore the signals are less likely to be overlapping in the resulting spectrum. This increased resolution is a significant advantage for analysis. (Larger-field machines are also favoured on account of having intrinsically higher signal arising from the
Boltzmann distribution of
magnetic spin states.)
Chemical shift referencing
Chemical shift is usually expressed in
parts per million (ppm) by
frequency
Frequency is the number of occurrences of a repeating event per unit of time. Frequency is an important parameter used in science and engineering to specify the rate of oscillatory and vibratory phenomena, such as mechanical vibrations, audio ...
, because it is calculated from
:
where is the absolute resonance frequency of the sample, and is the absolute resonance frequency of a standard reference compound, measured in the same applied magnetic field . Since the numerator is usually expressed in
hertz
The hertz (symbol: Hz) is the unit of frequency in the International System of Units (SI), often described as being equivalent to one event (or Cycle per second, cycle) per second. The hertz is an SI derived unit whose formal expression in ter ...
, and the denominator in
megahertz
The hertz (symbol: Hz) is the unit of frequency in the International System of Units (SI), often described as being equivalent to one event (or cycle) per second. The hertz is an SI derived unit whose formal expression in terms of SI base ...
, is expressed in ppm.
The detected frequencies (in Hz) for
1H,
13C, and
29Si nuclei are usually referenced against TMS (
tetramethylsilane), TSP (
trimethylsilylpropanoic acid), or
DSS, which by the definition above have a chemical shift of zero if chosen as the reference. Other standard materials are used for setting the chemical shift for other nuclei.
Thus an NMR signal observed at a frequency 300 Hz higher than the signal from TMS, where the TMS resonance frequency is 300 MHz, has a chemical shift of
:
Although the absolute resonance frequency depends on the applied magnetic field, the chemical shift is independent of external magnetic field strength. On the other hand, the resolution of NMR will increase with applied magnetic field.
Referencing methods
Practically speaking, diverse methods may be used to reference chemical shifts in an NMR experiment, which can be subdivided into ''indirect'' and ''direct'' referencing methods.
Indirect referencing uses a channel other than the one of interest to adjust chemical shift scale correctly, i.e. the solvent signal in the deuterium (lock) channel can be used to reference the a
1H NMR spectrum.
Both indirect and direct referencing can be done as three different procedures:
# Internal referencing, where the reference compound is added directly to the system under study."
In this common practice, users adjust residual solvent signals of
1H or
13C NMR spectra with calibrated spectral tables. If substances other than the solvent itself are used for internal referencing, the sample has to be combined with the reference compound, which may affect the chemical shifts.
# External referencing, involving sample and reference contained separately in coaxial cylindrical tubes.
With this procedure, the reference signal is still visible in the spectrum of interest, although the reference and the sample are physically separated by a glass wall. Magnetic susceptibility differences between the sample and the reference phase need to be corrected theoretically,
which lowers the practicality of this procedure.
# Substitution method: The use of separate cylindrical tubes for the sample and the reference compound, with (in principle) spectra recorded individually for each.
Similar to external referencing, this method allows referencing without sample contamination. If field/frequency locking via the
2H signal of the deuterated solvent is used and the solvents of reference and analyte are the same, the use of this methods is straightforward. Problems may arise if different solvents are used for the reference compound and the sample as (just like for external referencing) magnetic susceptibility differences need to be corrected theoretically.
If this method is used without field/frequency locking, shimming procedures between the sample and the reference need to be avoided as they change the applied magnetic field (and thereby influence the chemical shift).
Modern NMR spectrometers commonly make use of the absolute scale,
which defines the
1H signal of
TMS as 0 ppm in proton NMR and the center frequencies of all other nuclei as percentage of the TMS resonance frequency:
:
The use of the deuterium (lock) channel, so the
2H signal of the deuterated solvent, and the Ξ value of the absolute scale is a form of internal referencing and is particularly useful in heteronuclear NMR spectroscopy as local reference compounds may not be always be available or easily used (i.e. liquid NH
3 for
15N NMR spectroscopy). This system, however, relies on accurately determined
2H NMR chemical shifts enlisted in the spectrometer software and correctly determined Ξ values by IUPAC.
A recent study for
19F NMR spectroscopy revealed that the use of the absolute scale and lock-based internal referencing led to errors in chemical shifts.
These may be negated by inclusion of calibrated reference compounds.
The induced magnetic field
The electrons around a nucleus will circulate in a magnetic field and create a secondary
induced magnetic field. This field opposes the applied field as stipulated by
Lenz's law and atoms with higher induced fields (i.e., higher electron density) are therefore called ''shielded'', relative to those with lower electron density.
Electron-donating alkyl groups, for example, lead to increased shielding whereas
electron-withdrawing substituents such as
nitro groups lead to ''deshielding'' of the nucleus. Not only substituents cause local induced fields. Bonding electrons can also lead to shielding and deshielding effects. A striking example of this is the
pi bonds in
benzene
Benzene is an Organic compound, organic chemical compound with the Chemical formula#Molecular formula, molecular formula C6H6. The benzene molecule is composed of six carbon atoms joined in a planar hexagonal Ring (chemistry), ring with one hyd ...
. Circular current through the
hyperconjugated system causes a shielding effect at the molecule's center and a deshielding effect at its edges. Trends in chemical shift are explained based on the degree of shielding or deshielding.
Nuclei are found to resonate in a wide range to the left (or more rare to the right) of the internal standard. When a signal is found with a higher chemical shift:
* The applied effective magnetic field is lower, if the resonance frequency is fixed (as in old traditional CW spectrometers)
* The frequency is higher, when the applied magnetic field is static (normal case in FT spectrometers)
* The nucleus is more deshielded
* The signal or shift is downfield or at low field or paramagnetic.
Conversely a lower chemical shift is called a diamagnetic shift, and is upfield and more shielded.
Diamagnetic shielding
In real molecules protons are surrounded by a cloud of charge due to adjacent bonds and atoms. In an applied magnetic field () electrons circulate and produce an induced field () which opposes the applied field. The effective field at the nucleus will be . The nucleus is said to be experiencing a diamagnetic shielding.
Factors causing chemical shifts
Important factors influencing chemical shift are electron density,
electronegativity
Electronegativity, symbolized as , is the tendency for an atom of a given chemical element to attract shared electrons (or electron density) when forming a chemical bond. An atom's electronegativity is affected by both its atomic number and the ...
of neighboring groups and anisotropic induced magnetic field effects.
Electron density shields a nucleus from the external field. For example, in proton NMR the electron-poor
tropylium ion has its protons downfield at 9.17 ppm, those of the electron-rich
cyclooctatetraenyl anion move upfield to 6.75 ppm and its dianion even more upfield to 5.56 ppm.
A nucleus in the vicinity of an
electronegative atom experiences reduced electron density and the nucleus is therefore deshielded. In
proton NMR of
methyl halides (CH
3X) the chemical shift of the methyl protons increase in the order from 2.16 ppm to 4.26 ppm reflecting this trend. In
carbon NMR the chemical shift of the carbon nuclei increase in the same order from around −10 ppm to 70 ppm. Also when the electronegative atom is removed further away the effect diminishes until it can be observed no longer.
Anisotropic
Anisotropy () is the structural property of non-uniformity in different directions, as opposed to isotropy. An anisotropic object or pattern has properties that differ according to direction of measurement. For example, many materials exhibit ver ...
induced magnetic field effects are the result of a local induced magnetic field experienced by a nucleus resulting from circulating electrons that can either be paramagnetic when it is parallel to the applied field or diamagnetic when it is opposed to it. It is observed in
alkenes where the double bond is oriented perpendicular to the external field with pi electrons likewise circulating at right angles. The induced magnetic field lines are parallel to the external field at the location of the alkene protons which therefore shift downfield to a 4.5 ppm to 7.5 ppm range. The three-dimensional space where a diamagnetic shift is called the shielding zone with a cone-like shape aligned with the external field.
:
The protons in
aromatic compounds are shifted downfield even further with a signal for
benzene
Benzene is an Organic compound, organic chemical compound with the Chemical formula#Molecular formula, molecular formula C6H6. The benzene molecule is composed of six carbon atoms joined in a planar hexagonal Ring (chemistry), ring with one hyd ...
at 7.73 ppm as a consequence of a
diamagnetic ring current.
Alkyne protons by contrast resonate at high field in a 2–3 ppm range. For alkynes the most effective orientation is the external field in parallel with electrons circulation around the triple bond. In this way the acetylenic protons are located in the cone-shaped shielding zone hence the upfield shift.
:
Magnetic properties of most common nuclei
1H and
13C are not the only nuclei susceptible to NMR experiments. A number of different nuclei can also be detected, although the use of such techniques is generally rare due to small relative sensitivities in NMR experiments (compared to
1H) of the nuclei in question, the other factor for rare use being their slender representation in nature and organic compounds.
1H,
13C,
15N,
19F and
31P are the five nuclei that have the greatest importance in NMR experiments:
*
1H because of high sensitivity and vast occurrence in organic compounds
*
13C because of being the key component of all organic compounds despite occurring at a low abundance (1.1%) compared to the major isotope of carbon
12C, which has a spin of 0 and therefore is NMR-inactive.
*
15N because of being a key component of important biomolecules such as
protein
Proteins are large biomolecules and macromolecules that comprise one or more long chains of amino acid residue (biochemistry), residues. Proteins perform a vast array of functions within organisms, including Enzyme catalysis, catalysing metab ...
s and
DNA
*
19F because of high relative sensitivity
*
31P because of frequent occurrence in organic compounds and moderate relative sensitivity
Chemical shift manipulation
In general, the associated increased signal-to-noise and resolution has driven a move towards increasingly high field strengths. In limited cases, however, lower fields are preferred; examples are for systems in chemical exchange, where the speed of the exchange relative to the NMR experiment can cause additional and confounding linewidth broadening. Similarly, while avoidance of
second order coupling is generally preferred, this information can be useful for elucidation of chemical structures. Using refocussing pulses placed between recording of successive points of the
free induction decay, in an analogous fashion to the
spin echo technique in MRI, the chemical shift evolution can be scaled to provide apparent low-field spectra on a high-field spectrometer. In a similar fashion, it is possible to upscale the effect of J-coupling relative to the chemical shift using pulse sequences that include additional J-coupling evolution periods interspersed with conventional spin evolutions.
Other chemical shifts
The
Knight shift (first reported in 1949) and
Shoolery's rule are observed with pure metals and
methylene groups, respectively. The NMR chemical shift in its present-day meaning first appeared in journals in 1950. Chemical shifts with a different meaning appear in
X-ray photoelectron spectroscopy as the shift in atomic core-level energy due to a specific chemical environment. The term is also used in
Mössbauer spectroscopy, where similarly to NMR it refers to a shift in peak position due to the local chemical bonding environment. As is the case for NMR the chemical shift reflects the electron density at the atomic nucleus.
See also
*
EuFOD, a shift agent
*
MRI
*
Nuclear magnetic resonance
*
Nuclear magnetic resonance spectroscopy of carbohydrates
*
Nuclear magnetic resonance spectroscopy of nucleic acids
*
Nuclear magnetic resonance spectroscopy of proteins
*
Random coil index
*
Relaxation (NMR)
*
Solid-state NMR
*
TRISPHAT, a chiral shift reagent for cations
*
Zeeman effect
References
External links
chem.wisc.eduBioMagResBankNMR Table* Online tutorials (these generally involve combined use of
IR,
1H NMR,
13C NMR and
mass spectrometry)
Problem set 1(see also thi
for more background information on spin-spin coupling)