HOME

TheInfoList



OR:

Boiler feedwater is the water which is supplied to a
boiler A boiler is a closed vessel in which fluid (generally water) is heated. The fluid does not necessarily boil. The heated or vaporized fluid exits the boiler for use in various processes or heating applications, including water heating, centra ...
. The feed water is put into the steam drum from a feed pump. In the steam drum the feed water is then turned into steam from the heat. After the steam is used, it is then dumped to the main condenser. From the condenser, it is then pumped to the deaerated feed tank. From this tank it then goes back to the steam drum to complete its cycle. The feedwater is never open to the atmosphere. This cycle is known as a
closed system A closed system is a natural physical system that does not allow transfer of matter in or out of the system, althoughin the contexts of physics, chemistry, engineering, etc.the transfer of energy (e.g. as work or heat) is allowed. Physics In cl ...
or
Rankine cycle The Rankine cycle is an idealized thermodynamic cycle describing the process by which certain heat engines, such as steam turbines or reciprocating steam engines, allow mechanical work to be extracted from a fluid as it moves between a heat sour ...
.


History of feedwater treatment

During the early development of boilers, water treatment was not so much of an issue, as temperatures and pressures were so low that high amounts of scale and rust would not form to such a significant extent, especially if the boiler was “ blown down”. It was general practice to install zinc plates and/or
alkaline In chemistry, an alkali (; from the Arabic word , ) is a basic salt of an alkali metal or an alkaline earth metal. An alkali can also be defined as a base that dissolves in water. A solution of a soluble base has a pH greater than 7.0. The ...
chemicals to reduce corrosion within the boiler. Many tests had been performed to determine the cause (and possible protection) from corrosion in boilers using distilled water, various chemicals, and sacrificial metals.
Silver nitrate Silver nitrate is an inorganic compound with chemical formula . It is a versatile precursor to many other silver compounds, such as those used in photography. It is far less sensitive to light than the halides. It was once called ''lunar causti ...
can be added to feedwater samples to detect contamination by
seawater Seawater, or sea water, is water from a sea or ocean. On average, seawater in the world's oceans has a salinity of about 3.5% (35 g/L, 35 ppt, 600 mM). This means that every kilogram (roughly one liter by volume) of seawater has approximat ...
. Use of lime for alkalinity control was mentioned as early as 1900, and was used by the French and British Navies until about 1935. In modern boilers, treatment of feedwater is critical, as problems result from using untreated water in extreme pressure and temperature environments. This includes lower efficiency in terms of heat transfer, overheating, damage, and costly cleaning.


Characteristics of boiler feedwater

Water has a higher
heat capacity Heat capacity or thermal capacity is a physical property of matter, defined as the amount of heat to be supplied to an object to produce a unit change in its temperature. The SI unit of heat capacity is joule per kelvin (J/K). Heat capacity is a ...
than most other substances. This quality makes it an ideal raw material for boiler operations. Boilers are part of a closed system as compared to open systems in a
gas turbine A gas turbine or gas turbine engine is a type of Internal combustion engine#Continuous combustion, continuous flow internal combustion engine. The main parts common to all gas turbine engines form the power-producing part (known as the gas gene ...
. The
closed system A closed system is a natural physical system that does not allow transfer of matter in or out of the system, althoughin the contexts of physics, chemistry, engineering, etc.the transfer of energy (e.g. as work or heat) is allowed. Physics In cl ...
that is used is the
Rankine cycle The Rankine cycle is an idealized thermodynamic cycle describing the process by which certain heat engines, such as steam turbines or reciprocating steam engines, allow mechanical work to be extracted from a fluid as it moves between a heat sour ...
. This means that the water is recirculated throughout the system and is never in contact with the atmosphere. The water is reused and needs to be treated to continue efficient operations.
Boiler water Boiler water is liquid water within a boiler, or in associated piping, pumps and other equipment, that is intended for evaporation into steam. The term may also be applied to raw water intended for use in boilers, treated boiler feedwater, steam c ...
must be treated in order to be proficient in producing steam, as well as preventing scaling,
corrosion Corrosion is a natural process that converts a refined metal into a more chemically stable oxide. It is the gradual deterioration of materials (usually a metal) by chemical or electrochemical reaction with their environment. Corrosion engine ...
, foaming, and priming. Chemicals are put into boiler water through the chemical feed tank to keep the water within chemical range. These chemicals are mostly oxygen scavengers and
phosphates Phosphates are the naturally occurring form of the element phosphorus. In chemistry, a phosphate is an anion, salt, functional group or ester derived from a phosphoric acid. It most commonly means orthophosphate, a derivative of orthophosphor ...
. The boiler water also has frequent blowdowns in order to keep the chloride content down. The boiler operations also include bottom blows in order to get rid of solids. Scale is precipitated impurities out of the water and then forms on heat transfer surfaces. This is a problem because scale does not transfer heat very well and causes the tubes to fail by getting too hot. Corrosion is caused by oxygen in the water. The oxygen causes the metal to oxidize which lowers the melting point of the metal. Foaming and priming are caused when the boiler water does not have the correct amount of chemicals and suspended solids in the water which carry over in the dry pipe. The dry pipe is where the steam and water mixtures are separated.


Boiler feedwater treatment

Boiler water treatment is used to control alkalinity, prevent scaling, correct pH, and to control conductivity. The boiler water needs to be alkaline and not acidic, so that it does not ruin the tubes. There can be too much conductivity in the feed water when there are too many dissolved solids. These correct treatments can be controlled by efficient operator and use of treatment chemicals. The main objectives to treat and condition boiler water is to exchange heat without scaling, protect against scaling, and produce high quality steam. The treatment of boiler water can be put into two parts. These are internal treatment and external treatment. (Sendelbach, p. 131)Sendelbach, M. (1988). Boiler-water treatment: Why, what and how. Chemical Engineering, 95(11), 127. The internal treatment is for boiler feed water and external treatment is for make-up feed water and the condensate part of the system. Internal treatment protects against feed water hardness by preventing precipitating of scale on the boiler tubes. This treatment also protects against concentrations of dissolved and suspended solids in the feed water without priming or foaming. These treatment chemicals also help with the alkalinity of the feed water making it more of a base to help protect against boiler corrosion. The correct alkalinity is protected by adding phosphates. These phosphates precipitate the solids to the bottom of the boiler drum. At the bottom of the boiler drum there is a bottom blow to remove these solids. These chemicals also include anti-scaling agents, oxygen scavengers, and anti-foaming agents. Sludge can also be treated by two approaches. These are by coagulation and dispersion. When there is a high amount of sludge content it is better to coagulate the sludge to form large particles in order to just use the bottom blow to remove them from the feed water. When there is a low amount of sludge content it is better to use dispersants because it disperses the sludge throughout the feed water so sludge does not form.


Deaeration of feed water

Oxygen and carbon dioxide are removed from the feed water by deaeration. Deaeration can be accomplished by using deaerator heaters, vacuum deaerators, mechanical pumps, and steam-jet ejectors. In deaerating heaters, steam sprays incoming feed water and carries away the dissolved gases. The deaerators also store hot feed water which is ready to be used in the boiler. This means of mechanical deaeration is used with chemical oxygen scavenging agents to increase efficiency. (Sendelbach, p. 129) Deaerating heaters can be classified in two groups: spray types and tray types. With tray type heaters the incoming water is sprayed into steam atmosphere to reach saturation temperature. When the saturation temperature is reached most of the oxygen and non-condensable gases are released. There are seals that prevent the recontamination of the water in the spray section. The water then falls to the storage tank below. The non-condensables and oxygen are then vented to the atmosphere. The components of the tray type deaerating heater are a shell, spray nozzles, a direct contact vent condenser, tray stacks, and protective interchamber walls. The spray type deaerator is similar to the tray type deaerator. The water is sprayed into a steam atmosphere and most of the oxygen and non-condensables are released to the steam. The water then falls to the steam scrubber where the slight pressure loss causes the water to flash a little bit which also aids the removal of oxygen and non-condensables. The water then overflows to the storage tank. The gases are then vented to the atmosphere. With vacuum deaeration a vacuum is applied to the system and water is then brought to its saturation temperature. The water is sprayed into the tank like the spray and tray deaerators. The oxygen and non-condensables are vented to the atmosphere. (Sendelbach, p. 130)


Conditioning

The feedwater must be specially treated to avoid problems in the boiler and downstream systems. Untreated boiler feed water can cause corrosion and fouling.


Boiler corrosion

Corrosive compounds, especially O2 and CO2 must be removed, usually by use of a
deaerator A deaerator is a device that is used for the removal of dissolved gases like oxygen from a liquid. Thermal deaerators are commonly used to remove dissolved gases in feedwater for steam-generating boilers. The deaerator is part of the feedwater h ...
. Residual amounts can be removed chemically, by use of
oxygen scavenger Oxygen scavengers or oxygen absorbers are added to enclosed packaging to help remove or decrease the level of oxygen in the package. They are used to help maintain product safety and extend shelf life. There are many types of oxygen absorbers ...
s. Additionally, feed water is typically alkalized to a pH of 9.0 or higher, to reduce oxidation and to support the formation of a stable layer of
magnetite Magnetite is a mineral and one of the main iron ores, with the chemical formula . It is one of the iron oxide, oxides of iron, and is ferrimagnetism, ferrimagnetic; it is attracted to a magnet and can be magnetization, magnetized to become a ...
on the water-side surface of the boiler, protecting the material underneath from further corrosion. This is usually done by dosing alkaline agents into the feed water, such as
sodium hydroxide Sodium hydroxide, also known as lye and caustic soda, is an inorganic compound with the formula . It is a white solid ionic compound consisting of sodium cations and hydroxide anions . Sodium hydroxide is a highly corrosive base (chemistry), ...
(
caustic soda Sodium hydroxide, also known as lye and caustic soda, is an inorganic compound with the formula . It is a white solid ionic compound consisting of sodium cations and hydroxide anions . Sodium hydroxide is a highly corrosive base and alkali t ...
) or
ammonia Ammonia is an inorganic chemical compound of nitrogen and hydrogen with the chemical formula, formula . A Binary compounds of hydrogen, stable binary hydride and the simplest pnictogen hydride, ammonia is a colourless gas with a distinctive pu ...
. Corrosion in boilers is due to the presence of dissolved oxygen, dissolved carbon dioxide, or dissolved salts.


Fouling

Deposits reduce the heat transfer in the boiler, reduce the flow rate and eventually block boiler tubes. Any non- volatile salts and minerals that will remain when the feedwater is
evaporate Evaporation is a type of vaporization that occurs on the surface of a liquid as it changes into the gas phase. A high concentration of the evaporating substance in the surrounding gas significantly slows down evaporation, such as when hum ...
d must be removed, because they will become concentrated in the liquid phase and require excessive "blow-down" (draining) to prevent the formation of solid precipitates. Even worse are minerals that form scale. Therefore, the
make-up water Cosmetics are substances that are intended for application to the body for cleansing, beautifying, promoting attractiveness, or altering appearance. They are mixtures of chemical compounds derived from either Natural product, natural source ...
added to replace any losses of feedwater must be demineralized/
deionized water Purified water is water that has been mechanically filtered or processed to remove impurities and make it suitable for use. Distilled water was, formerly, the most common form of purified water, but, in recent years, water is more frequently pu ...
, unless a purge valve is used to remove dissolved minerals.


Caustic embrittlement


Priming and foaming


Locomotive boilers

Steam locomotives A steam locomotive is a locomotive that provides the force to move itself and other vehicles by means of the expansion of steam. It is fuelled by burning combustible material (usually coal, oil or, rarely, wood) to heat water in the locomot ...
usually do not have condensers so the feedwater is not recycled and water consumption is high. The use of deionized water would be prohibitively expensive so other types of water treatment are used. Chemicals employed typically include
sodium carbonate Sodium carbonate (also known as washing soda, soda ash, sal soda, and soda crystals) is the inorganic compound with the formula and its various hydrates. All forms are white, odourless, water-soluble salts that yield alkaline solutions in water ...
,
sodium bisulfite Sodium bisulfite (or sodium bisulphite, sodium hydrogen sulfite) is a chemical mixture with the approximate chemical formula NaHSO3. Sodium bisulfite is not a real compound, but a mixture of salts that dissolve in water to give solutions compose ...
,
tannin Tannins (or tannoids) are a class of astringent, polyphenolic biomolecules that bind to and Precipitation (chemistry), precipitate proteins and various other organic compounds including amino acids and alkaloids. The term ''tannin'' is widel ...
,
phosphate Phosphates are the naturally occurring form of the element phosphorus. In chemistry, a phosphate is an anion, salt, functional group or ester derived from a phosphoric acid. It most commonly means orthophosphate, a derivative of orthop ...
and an anti-foaming agent. Treatment systems have included: * Alfloc, developed by
British Railways British Railways (BR), which from 1965 traded as British Rail, was a state-owned company that operated most rail transport in Great Britain from 1948 to 1997. Originally a trading brand of the Railway Executive of the British Transport Commis ...
and
Imperial Chemical Industries Imperial Chemical Industries (ICI) was a British Chemical industry, chemical company. It was, for much of its history, the largest manufacturer in Britain. Its headquarters were at Millbank in London. ICI was listed on the London Stock Exchange ...
* Traitement Integral Armand (TIA), developed by
Louis Armand Louis François Armand (; 17 January 1905 – 30 August 1971) was a French engineer and senior civil servant who managed several public companies, as well as had a significant role in World War II as an officer in the Resistance. He became the ...
* Porta Treatment, developed by
Livio Dante Porta Livio Dante Porta (21 March 1922 – 10 June 2003) was an Argentine steam locomotive engineer. He is particularly remembered for his innovative modifications to existing locomotive systems in order to obtain better performance and energy effi ...


See also

* Boiler feedwater pump *
Evaporator An evaporator is a type of heat exchanger device that facilitates evaporation by utilizing conductive and convective heat transfer, which provides the necessary thermal energy for phase transition from liquid to vapour. Within evaporators, a ci ...
* Helamin


References

{{Reflist *Shun'an, C., Qing, Z., & Zhixin, Z. (2008). A study of the influence of chloride ion concentration on the corrosion behavior of carbon steel in phosphate high-temperature boiler water chemistries. Anti-Corrosion Methods and Materials, 55(1), 15–19. *Sendelbach, M. (1988). Boiler-water treatment: Why, what and how. Chemical Engineering, 95(11), 127. *Characteristics of boiler feed water. (n.d.). Retrieved March 21, 2015, from http://www.lenntech.com/applications/process/boiler/boiler-feedwater-characteristics.htm


External links


Boiler Feedwater System Configuration
Power station technology Boilers Chemical process engineering Steam locomotive technologies