HOME

TheInfoList



OR:

Automatic fire suppression systems control and extinguish
fire Fire is the rapid oxidation of a material (the fuel) in the exothermic chemical process of combustion, releasing heat, light, and various reaction products. At a certain point in the combustion reaction, called the ignition point, flames ...
s without human intervention. Examples of automatic systems include
fire sprinkler system A fire sprinkler system is an active fire protection method, consisting of a water supply system, providing adequate pressure and flowrate to a water distribution piping system, onto which fire sprinklers are connected. Although historically on ...
, gaseous fire suppression, and
condensed aerosol fire suppression Condensed aerosol fire suppression is a particle-based form of fire extinction. It is similar to dry chemical fire extinction). It employs a fire-extinguishing agent consisting of: very fine solid particles as well as gaseous matter. The cond ...
. When fires are extinguished in the early stages loss of life is minimal since 93% of all fire-related deaths occur once the fire has progressed beyond the early stages.


Types of automatic systems

Today there are numerous types of automatic fire suppression systems and standards for each one. Systems are as diverse as the many applications. In general, however, automatic fire suppression systems fall into two categories: ''engineered'' and ''pre-engineered'' systems. * Engineered fire suppression systems are design specific and most commonly used for larger installations where the system is designed for a particular application. Examples include large marine and land vehicle applications, server rooms, public and private buildings, industrial paint lines, dip tanks and electrical switch rooms. Engineered systems use a number of gaseous or solid agents with many of them being specifically formulated. Some are even stored as a
liquid A liquid is a nearly incompressible fluid that conforms to the shape of its container but retains a (nearly) constant volume independent of pressure. As such, it is one of the four fundamental states of matter (the others being solid, gas, ...
and discharged as a gas. * Pre-engineered fire suppression systems use pre-designed elements to eliminate the need for engineering work beyond the original product design. Typical industrial solutions use a wet or dry chemical agent, such as
potassium carbonate Potassium carbonate is the inorganic compound with the formula K2 CO3. It is a white salt, which is soluble in water. It is deliquescent, often appearing as a damp or wet solid. Potassium carbonate is mainly used in the production of soap and gl ...
or
monoammonium phosphate Ammonium dihydrogen phosphate (ADP), also known as monoammonium phosphate (MAP) is a chemical compound with the chemical formula (NH4)(H2PO4). ADP is a major ingredient of agricultural fertilizers and some fire extinguishers. It also has si ...
(MAP), to protect relatively smaller spaces such as distribution boards, battery rooms, engine bays, wind turbines, hazardous goods and other storage areas. A number of residential designs have also emerged that typically employ water mist and target retrofit applications.


Components

By definition, an automatic fire suppression system can operate without human intervention. To do so it must possess a means of detection, actuation and delivery. In many systems, detection is accomplished by mechanical or electrical means. Mechanical detection uses fusible-link or thermo-bulb detectors. These detectors are designed to separate at a specific temperature and release tension on a release mechanism. Electrical detection uses heat detectors equipped with self-restoring, normally-open contacts which close when a predetermined temperature is reached. Remote and local manual operation is also possible. Actuation usually involves either a pressurized fluid and a release valve, or in some cases an electric pump. Delivery is accomplished by means of piping and nozzles. Nozzle design is specific to the agent used and coverage desired.


Extinguishing agents

Water is the most prevalent fire suppression agent in use worldwide. However, the use of water does have some limitations, which can range from inadequate supplies (particularly in less developed regions) to operations and processes which are highly susceptible to water damage. In some cases, certain contents or processes (such as water-reactive chemicals or metals, molten materials, etc.) are truly incompatible with water; water discharge could lead to explosion. In these instances, alternative chemical compounds, inert gases and similar can be utilized for fire suppression as outlined below:


Health and environmental concerns

Despite their effectiveness, chemical fire extinguishing agents are not without disadvantages. In the early 20th century,
carbon tetrachloride Carbon tetrachloride, also known by many other names (such as tetrachloromethane, also recognised by the IUPAC, carbon tet in the cleaning industry, Halon-104 in firefighting, and Refrigerant-10 in HVACR) is an organic compound with the chemi ...
was extensively used as a dry cleaning solvent, a refrigerant and as a fire extinguishing agent. In time, it was found carbon tetrachloride could lead to severe health effects. From the mid-1960s Halon 1301 was the industry standard for protecting high-value assets from the threat of fire. Halon 1301 had many benefits as a fire suppression agent; it is fast-acting, safe for assets and required minimal storage space. Halon 1301's major drawbacks are that it depletes atmospheric
ozone Ozone (), or trioxygen, is an inorganic molecule with the chemical formula . It is a pale blue gas with a distinctively pungent smell. It is an allotrope of oxygen that is much less stable than the diatomic allotrope , breaking down in the l ...
and is potentially harmful to humans. Since 1987, some 191 nations have signed The
Montreal Protocol on Substances That Deplete the Ozone Layer The Montreal Protocol is an international treaty designed to protect the ozone layer by phasing out the production of numerous substances that are responsible for ozone depletion. It was agreed on 16 September 1987, and entered into force on ...
. The Protocol is an international treaty designed to protect the ozone layer by phasing out the production of a number of substances believed to be responsible for ozone depletion. Among these were
halogenated hydrocarbons The haloalkanes (also known as halogenoalkanes or alkyl halides) are alkanes containing one or more halogen substituents. They are a subset of the general class of halocarbons, although the distinction is not often made. Haloalkanes are widely us ...
often used in fire suppression. As a result, manufacturers have focused on alternatives to Halon 1301 and Halon 1211 (halogenated hydrocarbons). A number of countries have also taken steps to mandate the removal of installed Halon systems. Most notably these include Germany and Australia, the first two countries in the world to require this action. In both of these countries complete removal of installed Halon systems has been completed except for a very few essential-use applications. The
European Union The European Union (EU) is a supranational union, supranational political union, political and economic union of Member state of the European Union, member states that are located primarily in Europe, Europe. The union has a total area of ...
is currently undergoing a similar mandated removal of installed Halon systems.


History

The first
fire extinguisher A fire extinguisher is a handheld active fire protection device usually filled with a dry or wet chemical used to extinguish or control small fires, often in emergencies. It is not intended for use on an out-of-control fire, such as one which ha ...
patent was issued to Alanson Crane of Virginia on Feb. 10, 1863.Improved Apparatus for Extinguishing Fires in Buildings
/ref> The first
fire sprinkler system A fire sprinkler system is an active fire protection method, consisting of a water supply system, providing adequate pressure and flowrate to a water distribution piping system, onto which fire sprinklers are connected. Although historically on ...
was patented by H.W. Pratt in 1872. But the first practical automatic sprinkler system was invented in 1874 by
Henry S. Parmalee Henry S. Parmelee (c. 1846 – 1902), president of the Fair Haven and Westville Street Railway Company, was a piano maker from New Haven, Connecticut. He took the idea of Sir Hiram Maxim and then invented the second automatic fire sprinkler system ...
of New Haven, CT. He installed the system in a piano factory he owned.


Modern systems

Since the early 1990s manufacturers have successfully developed safe and effective Halon alternatives. These include
DuPont DuPont de Nemours, Inc., commonly shortened to DuPont, is an American multinational chemical company first formed in 1802 by French-American chemist and industrialist Éleuthère Irénée du Pont de Nemours. The company played a major role in ...
's FM-200, American Pacific’s Halotron, FirePro's FPC Compound, Plumis’ Automist and 3M's Novec 1230 Fire Protection Fluid. Generally, the Halon replacement agents available today fall into two broad categories, in-kind (gaseous extinguishing agents) or not in-kind (alternative technologies). In-kind gaseous agents generally fall into two further categories, halocarbons and inert gases. Not in-kind alternatives include such options as water mist or the use of early warning smoke detection systems.


References


External link


Substitutes in Total Flooding Agents

Automatic Fire Extinguishers and It’s Importance for Home Kitchens
{{Fire protection Active fire protection Firefighting equipment Fire suppression Safety equipment